Forum: F-16 Design & Construction

F110 AB Igniter System?



Search Search  Register Register  Private Messages Private Messages
guidelines Forum Guidelines
Post new topic   Reply to topic   Previous  1, 2
View previous topic Log in to check your private messages View next topic
Author Message
Obi_Offiah
PostPosted: Sep 14, 2009 - 07:17 PM Reply with quote Back to top
Active Member
Active Member


Joined: Mar 28, 2004 - 12:09 AM
Posts: 230

Status: Offline
Mushmouth wrote:
VarkVet wrote:

We had a loaner jet ( with GE 129) that spit that section of the flame holder out twice!


We had the same thing happen when we were in Saudi. Changed one for cracking in that same spot, changed it, and when we took it to that trim pad, burned through on the post install run!


Obi_Offiah wrote:
Its also interesting to note that some F110s have a small crossfire gutter between the inner and middle gutters, while others don't.


But during G.E.'s test phase, they determined that they want the fuel to be distributed from 5 points. So to keep it equal and even, they dropped on spraybar and now there are 4 spraybars per local distribitor.


When you mention the five points of fuel distribution, does this basically mean that there are five main fuel pipes feeding the 19 spraybars and pilot swirler cup?
 View user's profile Send private message  
 
Sponsor
New postPosted: May 23, 2013 - 9:08 PM Back to top
F-16.net Sponsor





  Send private message  
 
Mushmouth
PostPosted: Sep 19, 2009 - 05:51 AM Reply with quote Back to top
Senior member
Senior member


Joined: Jul 11, 2006 - 06:59 AM
Posts: 258

Status: Offline
Obi_Offiah wrote:
Mushmouth wrote:
VarkVet wrote:

We had a loaner jet ( with GE 129) that spit that section of the flame holder out twice!


We had the same thing happen when we were in Saudi. Changed one for cracking in that same spot, changed it, and when we took it to that trim pad, burned through on the post install run!


Obi_Offiah wrote:
Its also interesting to note that some F110s have a small crossfire gutter between the inner and middle gutters, while others don't.


But during G.E.'s test phase, they determined that they want the fuel to be distributed from 5 points. So to keep it equal and even, they dropped on spraybar and now there are 4 spraybars per local distribitor.


When you mention the five points of fuel distribution, does this basically mean that there are five main fuel pipes feeding the 19 spraybars and pilot swirler cup?


You got it. 5 distributors and 20 spraybars physically installed (19 attached to the flameholder and 1 in the pilot burner can).

_________________
00-06 Shaw GE-129
06-07 & 11-12 ROK GE-100
07-11 Dyess B1B GE-102
11-12 Kunsan GE-100
12-'' JBMDL CF-6
 View user's profile Send private message  
 